Purchase type: inventory/second-hand
Second, the technical specifications
Model AWI-6/8
Working chamber-station 3-station (75), the basket when the 6 o'clock/8 interchangeable
Wafer size 125mm/156mm
Film loading speed 2400-3600 pieces/hour
Control system of PLC programmable controller, 7 ' color touch screen
Power supply AC220V, single phase three-wire 50Hz
Total power 2.0KW
Overall dimension (length * width * height) 1430*760*2000
Can also be customized according to customer requirements
Third, the structure features
1, rack made of SUS304,2*50*50mm stainless steel square tube of frame d structure, fuselage panels: SUS 304, 1.5mm plates, electrostatic spraying of surface anti-corrosion material, succinctness appearance, smooth.
2, operation manually place a single-chip Silicon on water beds when sliding on the table, use the flow of water to make non-resistance of silicon wafers into basket, auto arrange. Avoid artificial inserted when damaged due to human factors, achieving hamper accurate, fast and easily. Film loading speed as the operator rhythm may be, thereby greatly improving the production efficiency.
Basket positioning fixture unique to 3, with mild deformation of box with correction function, can readily adapt to 6 o'clock/8 wafer rapid transformation, converting times in 10 minutes, easy operation, reliable work.
4, silicon chip buffer block can effectively avoid impact damage of silicon chip into the box.
5, operate small water tank heating apparatus for plate, adjustable water temperature: room temperature to + 30 degrees centigrade.
6, equipment operation program, wafer boxes for different varieties (including mild deformation cassette) separate stroke settings and adjustment of the spacing. To meet different wafer boxed varieties.
7, system for circulating water, emissions-free.
8, a unique water spray device can be mounted on silicon chips in the process at any time maintain wafer wet spray.
9, the device is equipped with special water gun for cleaning water tanks.
10, the machine an external power supply installations, water intake, air intake, drainage, exhaust pipe configuration installed separately.